Electromagnetic Compatibility
EMC laboratories in EVPÚ a.s. belong to top-level workstations for EMC measurement. We provide type examinations of developed devices in accredited laboratories with state of the art measuring equipment and in large chambers. Our laboratories provide:
Measurement of:
- Low-frequency emissions
- Interference terminal voltage
- Interference field strength
- Radiated interference power
Measurement of resistance against:
- Electrostatic discharges
- Radiated high-frequency electromagnetic field
- Fast transients (Bursts)
- Surges
- Interference induced by high-frequency fields propagated through lines
- Magnetic field of mains frequency
- Short time voltage drops, short interruptions and voltage fluctuations
Semi-anechoic chamber
Dimensions (l x w x h): 20,5 m x 12,4 m x 7,80 m
Anechoic chamber
Dimensions (l x w x h): 7,30m x 3,40m x 3,60m
Radiation tests: Frequency range: 9 kHz – 26 GHz
Test of radiation through lines: Frequency range: 9 kHz – 30 MHz
- Tests of resistance against HF electromagnetic field: Frequency range: 26 MHz – 18 GHz
- Tests of resistance against electrostatic discharge: Air: to 25 kV; Contact: to 15 kV
- Tests of resistance against interference induced by high-frequency fields propagated through lines: Frequency range: 150 kHz – 230 MHz
- Tests of resistance against surges: to 7 kV
- Tests of resistance against bursts/groups of pulses: to 5500
Measurement of radio equipment:
- Frequency error
- Carrier power
- Effective radiated power
- Interference emissions
- Frequency stability
- Modulation bandwidth
Files for download: